Section3
Setting the Logging Conditions
■ I/O RESULT
Set this item when you want to apply a trigger by the input result (e.g. trigger input)
from a controller on a specific CH assigned as the source or by the output result (HIGH/
PASS/LOW/, etc.).
FUN Mode-[LOGGING]-[TRIGGER]-[START]-[I/O]
SOURCE
I/O SEL
ACTIVE
DELAY
ZS-DSU
3-20
User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting
Select the source to be used as the logging start trigger.
Range: SourceA to J
Select which I/O signal on the channel assigned as the selected source is
to be used as the start trigger.
Range: IN0 to IN3, OUT0 to OUT4
Sets the change in state of the signal, from ON to OFF or from OFF to ON,
to be taken as the trigger.
Range: OFF→ ON, ON→ OFF (default value: OFF→ ON)
At OFF
At ON
Set the delay time when you want to start logging a little before or a little
after the start trigger.
Range: -9999 to 9999 (ms) (default value: 0 ms)
At -9999ms
At 9999ms
Description
ON
OFF
ON
Logging start
OFF
Logging start
-9999ms
Delay time
Start trigger
Logging start
Logging start
+9999ms
Measured value