3 Start normal recording (normal recording
into slot A).
Press any of the [REC] buttons.
0
Recording into the media in slot A starts.
0
(The characters "RREC" appear in red.)
The card icon of slot A turns red (unselected
0
state), and the status indicator of slot A blinks
in red.
Red (not selected)
SDI IN
282min
100min
1080 /30p
50min
100min
50min
COMPRESS
ITU709
1 /64
ND
AE ±
0
1 / 60
F2.8
.
4 Stop normal recording.
Press any of the [REC] buttons again.
0
Recording to slot A stops, and the card slot
0
mark of slot A turns white (unselected state).
The characters "RREC" (red) changes back
0
to "STBY" (white).
The status indicator of slot A goes out.
0
White (not selected)
SDI IN
282min
100min
1080 /30p
50min
100min
50min
COMPRESS
ITU709
1 /64
ND
AE ±
0
1 / 60
F2.8
ISO
.
00: 00: 00.00
5 . 6f t
12 :34 :56
K
ISO
B 5600
102400
00: 00: 00.00
5 . 6f t
12 :34 :56
K
B 5600
102400
5 Stop backup recording.
Select [STBY] in [System] B [Record Set] B
0
[Slot Mode] B [Backup Rec] and press the
Set button (R).
(A P164 [ Slot Mode ] )
You can also press the user button that is
0
assigned with "Backup Trig".
(A P113 [User Switch Set Item] )
Recording to Slot B or the expansion slot
0
stops, and the card slot mark of Slot B or the
expansion slot turns white (selected state).
The status indicator of slot B lights up in
0
green.
White
SDI IN
282min
100min
1080 /30p
50min
COMPRESS
ITU709
1 /64
ND
F2.8
.
Memo :
When one of the media has run out of free space
0
during backup recording, recording will stop
only for the card that is full.
When recording to each slot is stopped,
0
recording in the REGEN mode will be enabled
for the card slot in which recording started.
When recording is started in the other slot while
0
recording to one slot, the clip being recorded is
split and simultaneous recording to the other
card starts.
When either normal recording or backup
0
recording is stopped while both are in progress,
the clip in the slot where recording is still ongoing
will be split.
Although the clips are separated during
0
recording the clips can be seamlessly joined by
arranging them on the timeline of the editing
software since they are recorded seamlessly.
Clip Cutter Trig cannot be performed during
0
backup recording.
(A P96 [Splitting the Clips Freely (Clip Cutter
Trig)] )
When [Slot Mode] is set to "Backup Y" or
0
"Backup
", [Rec Mode] can only be set to
"Normal".
(A P163 [ Rec Mode ] )
00: 00: 00.00
5 . 6f t
12 :34 : 56
100min
50min
AE ±
0
1 / 60
K
ISO
B 5600
102400
Backup Rec
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-hc900chuGy-hc900stuGy-hc900rcheGy-hc900

Table of Contents