Io-Link Parameter Setting - SMC Networks ZK2-ZS L A Series Operation Manual

Digital pressure switch for vacuum
Table of Contents

Advertisement

■IO-Link parameter setting

○IODD file
IODD (I/O Device Description) is a definition file which provides all properties and parameters required for
establishing functions and communication of the device.
IODD includes the main IODD file and a set of image files such as vendor logo, device picture and device
icon.
The IODD file is shown below.
100 to -100[kPa]
*1: "yyyymmdd" indicates the file preparation date. yyyy is the year, mm is the month and dd is the date.
○Service data
The tables below indicate the parameters which can be read or written by simple access parameter
(direct parameters page) and ISDU parameters which are applicable to various parameters and
commands.
*: The parameter data of this product is the Big-Endian type.
When the transmission method of the upper communication is Little-Endian, the byte order will be changed.
●Direct parameter page 1
DPP1 address
0x07
0x08
0x09
0x0A
0x0B
Pressure range
0 to -101[kPa]
SMC-ZSE10-X148_149-yyyymmdd-IODD1.1
SMC-ZSE10F-X148_149-yyyymmdd-IODD1.1
Access
Parameter name
R
Vendor ID
R
Device ID
*1
IODD file
Default value (Dec)
0x0083(131)
0x0288(648)
0x0289(649)
-22-
Contents
"SMC Corporation"
"ZSE10-00-B(-M)-X148/149"
"ZSE10F-00-B(-M)-X148/149"
Doc. No. DOC1051887