●Device access lock parameters (Index 12)
The contents are as follows.
Data type: 16 bit Record
Value (Dec)
0x0000(0)
Key lock release, Data storage unlock (Default value)
0x0002(2)
Key lock release, Data storage lock
0x0008(8)
Key lock, Data storage unlock
0x000A(10)
Key lock, Data storage lock
[Key lock]
This function prevents the user from physically changing the setting of the pressure switch (button
operation is not accepted).
Even when key lock function is activated, settings can be changed by IO-Link communication.
Restoration of data storage (overwriting parameter data) can be performed.
[Data storage lock (DS lock)]
Locking "Data storage" will invalidate the data storage function of the pressure switch.
In this case, access will be denied for backup and restoration of data storage.
●Device status parameters (Index 36)
Readable device states are as follows.
Data type: 8 bit UInteger
Value (Dec)
0x00(0)
Normal operation
0x01(1)
Maintenance/inspection required
0x02(2)
Outside specification range
0x03(3)
Function check
0x04(4)
Failure
●Device detail status parameters (Index 37)
Detailed event contents of readable device status are as follows.
Array
1
Internal failure of digital pressure switch
2
Internal failure of digital pressure switch
3
Internal failure of digital pressure switch
4
Internal failure of digital pressure switch
5
Internal failure of digital pressure switch
Internal failure of digital pressure switch SW1
6
(short circuit for release valve)
Internal failure of digital pressure switch SW2
7
(short circuit for supply valve)
8
Over the upper limit of the device temperature
9
Valve warning - release operation
10
Valve warning - valve protection function
11
Over the upper limit of the pressure range
12
Over the lower limit of the pressure range
13
14
15
Data storage upload request
Contents
Status definition
Event content
-
-
-24-
Description
-
Not available
Over the upper limit of the device temperature
Over the upper limit of the pressure range
Over the lower limit of the pressure range
Not available
Internal failure of digital pressure switch
Event classification
Definition
Value
Error
0xF4
Error
0xF4
Error
0xF4
Error
0xF4
Error
0xF4
Error
0xF4
Error
0xF4
Error
0xF4
Warning
0xE4
Warning
0xE4
Warning
0xE4
Warning
0xE4
-
0x00
-
0x00
Notification
0x54
Event code
0x8D03
0x8D04
0x8D05
0x8D01
0x8D06
0x8CE0
0x8CC0
0x8CD1
0x8DA0
0x8DA1
0x8C10
0x8C30
0x0000
0x0000
0xFF91
Doc. No. DOC1051887