SMC Networks ZK2-ZS L A Series Operation Manual page 28

Digital pressure switch for vacuum
Table of Contents

Advertisement

●Detailed product individual parameters (continued)
[F0] PoE (Output process data during communication error parameter) (Index 2310)
Sub index Data type
Access
0
U8
[F80] ECo (Power saving mode parameter) (Index 2400)
Sub index Data type
Access
0
U8
[F81] Security code (Security code parameter) (Index 2410)
Sub index Data type
Access
1
U8
2
U16
[F0] ord (Output priority) (Index 4000)
Sub index Data type
Access
0
U8
[F0] Cnt (Energy saving control parameter) (Index 4010)
Sub index Data type
Access
0
U8
The energy saving operation is not available for ZB series, this parameter should be set to 0 (off).
Default value
(dec)
Setting of output process data during IO-Link communication error.
0x00
R/W
0: off
(0)
1: hold
Default value
(dec)
Setting of pawer setting mode
0: off
0x00
R/W
1: on1 (the brightness of the whole display is reduced)
(0)
2: on2 (When there is no operation for 30 minutes, the display is off.
Default value
(dec)
Setting of pincode usage when Device Access Lock (Local User Interface lock) is
0x00
unlocked
R/W
(0)
0: Unused
1: Used
0x0000
Setting of security code
R/W
(0)
Setting range: 0 to 999
Default value
(dec)
Setting the priority operation when a vacuum instruction and a release instruction are
input simultaneously.
0x00
R/W
0: Vacuum
(0)
1: Release
2: No priority
Default value
(dec)
Setting of energy saving control. Refer to "example of ejector operation".
0x00
0:off
R/W
(0)
1:on
Only the decimal point flashes.)
-27-
Description
Description
Description
Description
Description
Doc. No. DOC1051887

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zb1-zs l a seriesZl3-vp 1 l a seriesZq-zs l a series

Table of Contents