SMC Networks ZK2-ZS L A Series Operation Manual page 20

Digital pressure switch for vacuum
Table of Contents

Advertisement

Pressure measurement value
•Pressure Range: 0 to -101[kPa]
Pressure display
Bit 31-16 (Dec)
(unused)
0x1068 (4200)
-105
0x1064 (4196)
-104.9
...
...
0x0FC8 (4040)
-101.0
...
...
0x0008 (8)
-0.2
0x0004 (4)
-0.1
0x0000 (0)
0
0xFFFC (-4)
0.1
0xFFF8 (-8)
0.2
...
...
0xFE74 (-396)
9.9
0xFE70 (-400)
10.0
(unused)
0x1069 to 0xFE6F is unused.
○Output process data
This product process data consists of valve instruction and parameter forced off instruction.
(Refer to the table below.)
Output process data
Bit offset
0
Vacuum instruction
1
Release instruction
2
Energy saving function forced off
3
Valve protection function forced off
4
Automatic release function forced off
5 to 15
value[kPa]
HHH
LLL
Item
Reserved
Pressure Range: 100 to -100[kPa]
Pressure display
Bit 31-16 (Dec)
(unused)
0x1068 (4200)
-105
0x1064 (4196)
-104.9
...
...
0x0FA0 (4000)
-100.0
...
...
0x0008 (8)
-0.2
0x0004 (4)
-0.1
0x0000 (0)
0
0xFFFC (-4)
0.1
0xFFF8 (-8)
0.2
...
...
0xF060 (-4000)
100.0
...
...
0xEF9C (-4196)
104.9
0xEF98 (-4200)
105
(unused)
0x1069 to 0xEF97 is unused.
0: Vacuum instruction OFF
1: Vacuum instruction ON
0: Release instruction OFF
1: Release instruction ON
0: Energy saving function depends on the parameter setting.
1: Energy saving function forced off
0: Valve protection function depends on the parameter setting.
1: Valve protection function forced off
0: Automatic release function depends on the parameter setting.
1: Automatic release function forced off
-
-19-
value[kPa]
HHH
LLL
Description
Doc. No. DOC1051887

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zb1-zs l a seriesZl3-vp 1 l a seriesZq-zs l a series