4.5.3
Frequency command with sign (Pr.541)
By frequency command with sign, start command (forward rotation/reverse rotation) can be inversed to operate.
Make selection of sign for the frequency command from RWw1.
Pr.
541
Frequency command sign selection
Speed setting using
Pr.541
Pr.37 and Pr.144
setting
0
Not used
1
0
With
1
*1
Pr.811 is only available for the FR-A800 series.
• Relationship between the start command and sign (Pr.541="1")
Start command
Sign of the frequency command
+
Forward rotation
-
+
Reverse rotation
-
Name
Sign
Setting range
Not used
0 to 59000
-32768 to 32767
With
(two's complement)
Not used
0 to 65535
-32768 to 32767
With
(two's complement)
Initial value
Setting range
0
0, 1
0 to 590.00 Hz
-327.68 to 327.67 Hz
It depends on Pr.37, Pr.144, Pr.811
(in 1 or 0.1 increments)
Actual run command
Forward rotation
Reverse rotation
Reverse rotation
Forward rotation
Actual frequency command
*1
.
INVERTER SETTING
4
47