 Relationship between the Pr.804 setting, the setting range, and the actual torque command /
torque limit (when setting is made from CC-Link communication)
Pr.804 setting
1, 3
600 to 1400 (1% increments)
5, 6
-32768 to 32767 (two's complement)
*1
The torque limit setting is defined as an absolute value.
 Supported inverters
The settings of Pr.810="2" (Internal torque limit 2) and Pr.544="24, 28, or 128" can be set only when the inverter supports the
internal torque limit 2. For inverter's support of the internal torque limit 2, refer to the Instruction Manual of the inverter.
Setting range
*1
*1
Actual torque command
-400 to 400%
-327.68 to 327.67%
DETAILS OF INPUT AND OUTPUT SIGNALS
Actual torque limit
0 to 400%
0 to 327.67%