Turning Off The Multi-Layered Section Changeover Function By The Number Of Stitching - JUKI PLC-2710V Instruction Manual

Table of Contents

Advertisement

8-8-2. Turning OFF the multi-layered section changeover function by the number of stitching

If the sensor value drops below the "multi-layered section changeover function OFF threshold" setting, while
the multi-layered section detection is enabled, the sewing parameter automatically returns to the previous
one which is used before turning ON the multi-layered section changeover function.
The aforementioned changeover timing can be changed by setting the number of stitches.
Once the number of stitches for turning OFF the multi-layered section changeover function is set, the sen-
sor value returns to the previous one which is used before turning ON the multi-layered section changeover
function, after the sewing machine sews the number of stitches from the position at which a multi-layered
section is detected even when the detection position is within the multi-layered section of material.
Note that if the sensor value drops below the "multi-layered section changeover function OFF threshold" set-
ting for the multi-layered section detection even within the range of the number of stitches setting, the sewing
parameter returns to the previous one which is used before turning ON the multi-layered section changeover
function.
<Sewing data edit screen>
<One-touch changeover function 4 edit screen>
– 106 –
[How to set]
❶ on the "Sewing data edit
1) Press
screen".
The "one-touch changeover function 4 edit
screen" is displayed.
❷ .
2) Press
The "number of stitches to turn OFF the
changeover function when the one-touch
changeover function is enabled" is displayed.

Advertisement

Table of Contents
loading

Table of Contents