Gas Solenoid Valve Removal; Pressure Regulator Removal - Viking RVGR3305B Service Manual

30 inch gas range
Hide thumbs Also See for RVGR3305B:
Table of Contents

Advertisement

Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Gas Solenoid Valve Removal

Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer's
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove back panel (see Back Panel Removal).
2. Mark and disconnect wires from solenoid valve.
3. Remove gas tubes from solenoid valve.
Note: Use care when removing gas tubes.
4. Remove screws and solenoid valve from range.
5. Reverse procedure for installation.
6. Perform gas leak test.
32

Pressure Regulator Removal

Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer's
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Shut off main gas supply to the range.
2. Remove back panel (see Back Panel Removal).
3. Remove tubing nut from pressure regulator.
4. Remove gas tubing from pressure regulator.
5. Remove screws and pressure regulator from range.
Gas shutoff, shown in
normally open position
6. Reverse procedure for installation.
Note: Use approved sealant when installing pressure
regulator.
7. Perform gas leak test.