Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

IRIS Module Removal

1. Access control components (see Control
Components Accessed).
2. Disconnect connectors from module.
3. Pull to remove module from burner valve.
4. Reverse procedure for installation.

Backguard Removal

1. Access the rear of the range.
2. Remove screws and backguard from range.
3. Reverse procedure for installation.
32

Surface Burner Valve Removal

Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer's
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Shut off main gas supply to the range.
2. Access control components (see Control
Components Accessed).
3. Pull to remove spark module from burner valve.
4. Remove tubing from back of burner valve.
5. Remove screw and burner valve from manifold
assembly.
6. For the stack burner valve, pull to remove the valve
switch from the valve.
7. Reverse procedure for installation.
8. Perform gas leak test.
©2012 Viking Preferred Service