Digital Operator Display
Cause
The Powerlink option card has been plugged
into option port CN5-B.
Digital Operator Display
Cause
Two or more input option cards (analog,
digital or communication) have been
connected to the drive at the same time.
Digital Operator Display
Cause
The POWERLINK option card has been
plugged into option port CN5-C
Digital Operator Display
Cause
Two or more input option cards (analog,
digital or communication) have been
connected to the drive at the same time.
YASKAWA Europe YEU TOEP C710616 87A - A1000 Option Powerlink - Installation Manual
9 Fault Diagnosis and Possible Solutions
Option Card Fault at Connector CN5-B
oFb00
Non-compatible option card is connected.
Always use option port CN5-A for communication option cards.
Option Card Fault at Connector CN5-B
oFb02
Two of the same option cards are connected at the same time.
Use either an analog input option AI-A3 or a digital input option DI-
A3 or a communication option card. Never use two of these cards at
the same time.
Option Card Fault at Connector CN5-C
Non-compatible option card is connected
oFc00
Drive is not processing the internal interface protocol. Drive does not
support Powerlink option card
Always use option port CN5-A for communication option cards.
Option Card Fault at Connector CN5-C
oFc02
Two of the same option cards are connected at the same time.
Use either an analog input option AI-A3 or a digital input option DI-
A3 or a communication option card. Never use two of these cards at
the same time.