Error History

1. Enter into Error History by first entering Diagnostics Mode and choosing the Error History from the Service Menu
(Key Press of 3).
2. Upon Entry to the Error History the Upper Information Line will display "Error History" and the lower information
line will display: " Press 1 to view error history, Press 2 to clear error history", if there is at least one error stored
in EE memory. If no errors are stored, this menu will display "No errors stored. Press CLEAR to return".
3. Choosing 1 will bring user to 1st error in the log, ENTER presses will jump through errors.
a. A key press of CLEAR while viewing the 1st error code will exit the viewing of the error codes and return to
the error code menu.
b. When there are no more error messages to display, the display will ask the user if it wants to go to Error #1
or back to Error History Menu.
c. ERROR HISTORY DISPLAY:
i.
The Entry Level Wall Oven will use error messages as opposed to error codes and will be displayed on
the LIL (Lower Information Line).
ii.
The UATD will display the record number of the error being displayed.
iii. The UIL will display the time stamp of the record being displayed.
4. Choosing 2 will display: (UIL) "Clear Error History?" (LIL) "Press 1=No, 2=Yes".
a. A choice of 1 will return the user to the initial Error History Entry Screen.
b. A choice of 2 will clear the history and display "No errors stored. Press CLEAR to return" in the lower infor-
mation line. The user can then use the "CLEAR" key to return to the Service Menu.
5. Exiting Error History can be done as follows:
a. CLEAR key press will return user to Service Menu from initial error history menu.
b. OVEN OFF (UPPER OFF or LOWER OFF) will exit diagnostics mode and return to TOD.
(NOTE: See Error History Chart (this section) for service instruction.

Version Information

1. Enter into Version Info by first entering Diagnostics Mode and choosing the Version Info from the Service Menu
(Key Press of 4).
2. Initial Entry will display "Version Info" in Upper Information line.
3. Lower Information line will display each of the following and can be switched using the ENTER key.
a. RM HV
b. RM LV
c. UIM
d. Cfg CRC
e. DATALOGGER VERSION
f.
S/N
4. Exiting the Version Info screen can be done in the following ways:
a. CLEAR key press from the RM HV display will return to the initial Service Menu.
b. OVEN OFF (LOWER OFF, UPPER OFF) will exit diagnostics mode and return LCD to TOD.
E E - - S S e e r r i i e e s s W W a a l l l l O O v v e e n n
E E - - S S e e r r i i e e s s W W a a l l l l O O v v e e n n
Troubleshooting Guide
5-7