Mitsubishi Electric FR-E8AXY E KIT Instruction Manual page 56

Table of Contents

Advertisement

NOTE
• Always calibrate the input after changing the input specification using Pr.73.
 Display unit changing for analog input (Pr.241)
• The analog input display unit (%/V) can be changed for analog input bias/gain calibration.
• Depending on the terminal input specification setting of Pr.73, the units of the displayed values of C17 (Pr.919) and C19
(Pr.920) change as shown below:
Analog command (terminal 1)
0 to 5 V input
0 to 10 V input
Pr.241 = "0 (initial value)"
0% to 100% (0.1%)
0% to 100% (0.1%)
Pr.241 = "1"
0 to 5 V (0.01 V)
0 to 10 V (0.01 V)
CONTROL CIRCUIT INPUT SIGNAL
3
55

Advertisement