 Relationship between the analog input terminal function and the calibration parameter
Pr.868
Terminal function
setting
Auxiliary frequency (speed)
0
setting
2
Regenerative driving torque limit
4
Torque limit
9999
(initial
No function
value)
 Changing the torque for the maximum analog input (C18 (Pr.920))
• Use C18 (Pr.920) to only change the torque setting (gain) for the maximum analog input voltage. (The C16 (Pr.919), C17
(Pr.919), and C19 (Pr.920) settings need not be changed.)
Bias setting
C12 (Pr.917) Terminal 1 bias frequency
(speed)
C13 (Pr.917) Terminal 1 bias (speed)
C16 (Pr.919) Terminal 1 bias command
(torque)
C17 (Pr.919) Terminal 1 bias (torque)
Calibration parameter
Gain setting
C14 (Pr.918) Terminal 1 gain frequency
(speed)
C15 (Pr.918) Terminal 1 gain (speed)
C18 (Pr.920) Terminal 1 gain command
(torque)
C19 (Pr.920) Terminal 1 gain (torque)