Changing the control mode with external terminals (MC signal)
• To use ON/OFF of the MC signal to switch the control mode, set Pr.800 or Pr.451. Refer to the FR-E800 Instruction Manual
(Function) and set Pr.800 or Pr.451. To input the MC signal, set "26" in any parameter from Pr.178 to Pr.189, or Pr.525 to
Pr.531 (Input terminal function selection) to assign the function.
• When an analog input terminal (terminal 1) is used for auxiliary speed setting or torque limit, switching of the control mode
changes the terminal function as follows:
Speed control / torque control switchover
Pr.868
Speed control
setting
(MC signal-OFF)
0
Auxiliary speed setting
Regenerative driving torque
2
limit
(Pr.810 = "1")
Torque limit
4
(Pr.810 = "1")
9999
(initial
—
value)
—: No function
*1
Available under Real sensorless vector control (Pr.800 = "12").
*2
Available under PM sensorless vector control (Pr.800 = "14").
34
CONTROL CIRCUIT INPUT SIGNAL
*1
Torque control
(MC signal-ON)
Speed limit assistance
—
—
—
Speed control / position control switchover
Speed control
(MC signal-OFF)
Auxiliary speed setting
Regenerative driving torque
limit
(Pr.810 = "1")
Torque limit
(Pr.810 = "1")
—
*2
Position control
(MC signal-ON)
—
Regenerative driving torque
limit
(Pr.810 = "1")
Torque limit
(Pr.810 = "1")
—