1.3

Specifications

 Input signal
 Digital input
Item
Number of terminals
Rated specification
 Pulse train input
Item
Number of terminals
Rated specification
 Analog input
Item
Number of terminals
Rated specification
Description
7
Input resistance: 4.7 kΩ
Voltage when contacts are open: 21 to 26 VDC
Current when contacts are short-circuited: 4 to 6 mADC
Description
1 (dual purpose with one digital input terminal)
Input resistance: 2 kΩ
Current when contacts are short-circuited: 8 to 13 mADC
Maximum input pulse: 100k pulses/s
Description
1
0 to ±10 VDC
Input resistance: 10 to 11 kΩ
Permissible maximum voltage: ±20 VDC