 Connection diagram
Sink logic
Inverter
STF
SOURCE
SINK
SD
24V
PC
FR-E8AXY
X1
24V
24V
S/S
SD
NOTE
• Terminal PC of the inverter is separated from the FR-E8AXY.
• Change the control logic of the inverter before installing the FR-E8AXY. For details, refer to the FR-E800 Instruction Manual
(Connection).
• The connection diagrams in this Instruction Manual appear with the control logic as sink logic (using the internal power
supply), unless otherwise specified.
26
CONTROL CIRCUIT INPUT SIGNAL
Source logic
Inverter
STF
SOURCE
SINK
SD
24V
PC
FR-E8AXY
X1
24V
24V
S/S
SD