NOTE
• When the slope of the frequency is changed after calibration of terminal 2 of the inverter, the slope of the frequency is also
changed for terminal 1 of the FR-E8AXY.
• When voltage is applied to terminal 1 while calibration of terminal 2 or terminal 4 is in progress, the terminal 1 input value is
added to the terminal 2 (4) input value.
• Always calibrate the input after changing the input specification using Pr.73.
 Display unit changing for analog input (Pr.241)
• The analog input display unit (%/V) can be changed for analog input bias/gain calibration.
• Depending on the terminal input specification setting of Pr.73, the units of the displayed values of C13 (Pr.917) and C15
(Pr.918) change as shown below:
Analog command (terminal 1)
0 to 5 V input
0 to 10 V input
44
CONTROL CIRCUIT INPUT SIGNAL
Pr.241 = "0 (initial value)"
0% to 100% (0.1%)
0% to 100% (0.1%)
Pr.241 = "1"
0 to 5 V (0.01 V)
0 to 10 V (0.01 V)