Tank Level Data; Generator Data; Load Cell Data - Raymarine LIGHTHOUSE 4 Operation Instructions Manual

Multifunction display operating system
Hide thumbs Also See for LIGHTHOUSE 4:
Table of Contents

Advertisement

• TWA & VMG wind
(1)
(True Wind Angle & Velocity Made Good)
• TWA & TWS
(True Wind Angle & True Wind Speed)
(1)
Note:
(1) Data item is only available in the Dashboard app

Tank level data

Tank level data shows the percentage fill for each detected tank.
The following data categories are available for tanks:
• [Fuel (Gasoline)]
• [Fresh water]
• [Live well]
• [Grey water]
• [Black water]
Each tank type has its own data category and if more than 1 tank of each type
is detected there will be subcategory for each tank.

Generator data

The generator data category is only available when a generator transmitting
supported NMEA 2000 PGNs is detected by the display.
The following data items are available in the [Generator] category:
• Engine load (PGN 127489)
• Engine RPM (PGN 127488)
• Fuel flow (PGN 127489)
• Coolant temperature (PGN 127489)
• Oil temperature (PGN 127489)
• Oil pressure (PGN 127489)
• Oil pressure (status) (PGN 127489)
• Generator battery voltage (PGN 127508)
• Engine hours (PGN 127489)
• Exhaust gas temperature (PGN 130316)
• Generator state (PGN 127750)
48
• Generator voltage (PGN 127751)
• Generator current (PGN 127751)
The data items above will be available for each detected generator.
• Generator line 1 power (PGN 127744)
• Generator line 1 current (PGN 127744)
• Generator line 1 to neutral voltage (PGN 127747)
• Generator line 1 to line 2 voltage (PGN 127747)
• Generator line 1 frequency (PGN 127747)
• Generator line 2 power (PGN 127745)
• Generator line 2 current (PGN 127745)
• Generator line 2 to neutral voltage (PGN 127748)
• Generator line 2 to line 3 voltage (PGN 127748)
• Generator line 2 frequency (PGN 127748)
• Generator line 3 power (PGN 127746)
• Generator line 3 current (PGN 127746)
• Generator line 3 to neutral voltage (PGN 127749)
• Generator line 3 to line 1 voltage (PGN 127749)
• Generator line 3 frequency (PGN 127749)
The additional data items above will be available for each detected 3 phase
generator.

Load cell data

Load cells are sensors used to measure the load bearings on key rigging
components, such as forestay, sidestay, backstay, or any sheet, halyard,
control line, vang, tack line, or runner.
A predefined list of [Load cells] is available.
For load cell data to be populated a supported load cell gateway is required.
Cyclops Marine load cells
Cyclops Marine is a third party company providing wireless load-sensing
devices for use in sailing, and especially race sailing.
The Cyclops Marine sensors connect wirelessly to the below-deck Cyclops
Marine Gateway, which interfaces with compatible Raymarine MFDs and
displays key load bearings at identified stress points on a yacht's rigging.

Advertisement

Table of Contents
loading