Chapter 5 Remote Interface Reference
Mx+B Scaling Overview
Mx+B Scaling Commands
CALCulate
:SCALe:GAIN <
:SCALe:GAIN? [(
Set the gain ("M") for scaled readings on the specified channels.
The maximum gain allowed is
The :GAIN? query returns the gain value on the specified channels.
CALCulate
:SCALe:OFFSet <
:SCALe:OFFSet? [(
Set the offset ("B") for scaled readings on the specified channels.
The maximum offset allowed is
The :OFFS? query returns the offset value on the specified channels.
CALCulate
:SCALe:UNIT <
:SCALe:UNIT? [(
Specify the custom label (e.g., RPM , PSI ) for scaled measurements on
the specified channels. You can specify a custom label with up to three
characters. You can use letters (A-Z), numbers (0-9), an underscore ( _ ),
or the "#" character which displays a degree symbol (
panel (displayed as a blank space in an output string from the remote
interface). The first character must be a letter or the "#" character
(the "#" character is allowed only as the leftmost character in the label).
The remaining two characters can be letters, numbers, or an underscore.
The following command shows how to add a custom label.
CALC:SCALE:UNIT 'PSI',(
Note: If you set the measurement label to
no effect on the temperature units set using the UNIT:TEMP command.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
gain
ch_list
>[,(
@
<
>)]
@
<
ch_list
>)]
±
1E+15. The default is M=1.
offset
ch_list
>[,(
@
<
>)]
@
<
ch_list
>)]
±
1E+15. The default is B=0.
quoted_string
ch_ list
>[,(
@
<
@
ch_ list
<
>)]
@
101)
°
°
C,
F, or K, note that this has
>)]
°
) on the front
245
5