Alarms and Relay Connections
6.1
Alarm Inputs
The AutoDome provides two alarm inputs. Each input can be activated by dry contact devices
such as pressure pads, passive infrared detectors, door contacts, and similar devices. The
table below summarizes the size and distance wires.
Wire Size
AWG
22
18
Table 6.1 Alarm wire guide
You wire alarms either Normally Open (N.O.) or Normally Closed (N.C.), and must program the
alarm inputs N.O. (the default) or N.C. through the Settings page (refer to the VG5 700 Series
User Manual).
6.2
Connecting Alarms (inputs 1 or 2)
You can configure alarms 1 and 2 as non-supervised Normally Open (N.O.) or Normally Closed
(N.C.) alarms.
6.2.1
Connecting a Normally Open Alarm
1.
2.
F.01U.215.779 | 1.0 | 2011.07
Maximum Distance
mm
feet
meters
0.644
500
152.4
1.024
800
243.8
Connect the alarm to the appropriate input (1 or 2) and ground at the AutoDome.
Figure 6.1 N.O. - Normally Open Non-supervised Connections
1
Dry Contact
2
Alarm Inputs 1 to 2
From the Alarm Connections page on the Settings Page (refer to the VG5 700 Series User
Manual) the Alarm Input # to N.O. See the table below for contact and condition details.
AutoDome Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm
Installation Manual
3
Dome Connector
4
Ground
AutoDome 700 Series IP PTZ Camera
Bosch Security Systems, Inc.