Bosch AutoDome 700 Series Installation Manual page 44

Ip ptz camera
Hide thumbs Also See for AutoDome 700 Series:
Table of Contents

Advertisement

44
en | Installing the Roof Parapet and Pipe Mounts
4.
1
Pin Description
1
2
3
4
5.
F.01U.215.779 | 1.0 | 2011.07
To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin
Alarms Out connector plugs with flying leads to the appropriate alarm wires. Then
connect the plugs to their mating connectors P103 and P102 on the Pipe Interface Board.
PIN
1
2
3
4
PIN
1
2
3
4
5
6
Figure 3.11 Alarm and Relay Connector Plugs
4-pin Alarm Connector
2
(P102)
Pin Description
Alarm Out 1
1
Alarm Out 2
2
Alarm Out 3‡
3
Alarm Ground
4
5
6
To connect supervised alarms and relays, attach the appropriate wires to their terminals
on the P104 connector on the Pipe Interface Board (see Figure 3.11, above). In addition,
refer to Section 6 Alarms and Relay Connections, page 60 for more details on wiring alarms
and relays.
Note: There is a slot located at the top of the Interface Board to tie the wires to the
circuit board with a cable tie.
Installation Manual
WHITE
BROWN
P102
ORANGE
GREEN
WHITE
BROWN
ORANGE
P103
GREEN
YELLOW
BLUE
6-pin Alarm In Connector
(P103)
Alarm In 3
Alarm In 4
Alarm In 5
Alarm In 6
Alarm In 7
Alarm Ground
AutoDome 700 Series IP PTZ Camera
1
2
3
4
5
6
7
P104
3
7-pin Relay Connector
(P104)
Pin Description
1
Alarm Out 4 Normally Open
2
Alarm Out 4 COM
3
Alarm Out 4 Normally Closed
4
Earth Ground
5
Analog Alarm 1
6
Analog Alarm 2
7
Ground