AutoDome 700 Series IP PTZ Camera
–
Bosch Security Systems, Inc.
The second method is to bypass the Power Supply Box and route the video, control, and
alarm wires directly to the Interface Board. You connect only the power wires inside the
Power Supply Box.
P101
24V NC
24V
P106
GND TXD RXD
Figure 3.4 VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box Connected to Pipe Interface Board
VG4-A-PSU1/VG4-A-PSU2
1
120 VAC/230 VAC Power In
2
P101 Connector
3
Ground Connection
4
Transformer
5
24 VAC Power Out
6
P107 Connector
Installation Manual
Installing the Roof Parapet and Pipe Mounts | en
J102
(LED)
P105
C+ C-
GND TXD RXD
C+ C-
Pipe Interface Board
7
P101 Connector
8
P107 Connector
9
24 VAC Power In (to AutoDome)
10
Earth Ground
11
24 VAC Power In (to AutoDome)
12
24 VAC Power In (to Heater)
13
24 VAC Power In (to Heater)
14
AutoDome Power
15
Heater Power
35
BNC
AGND
OUT 3
OUT 2
OUT 1
F.01U.215.779 | 1.0 | 2011.07