en | Connection
Ethernet Media Converter
Data Interface
Ethernet
Data Rate
10/100 Mbps
IEEE 802.3 Compliant
Full Duplex or Half Duplex Electrical Port
Full Duplex Optical Port
Fiber Type, MMF
50/125 µm MMF. For 50/125 µm fiber, subtract 4 dB from the specified optical budget
value. Must meet or exceed fiber standard ITU-T G.651.
Fiber Type, SMF
8–10/125 µm SMF. Must meet or exceed fiber standard ITU-T G.652.
Maximum Distance
20 km (12.4 miles)
Requirement
Media converter receiver (CNFE2MC/IN) at controller end of system
Terminal Connection Duplex LC or Single SC
10.5

Alarms and Relay Connections

Alarm Inputs
The camera provides two (2) alarm inputs. Each input can be activated by dry contact devices
such as pressure pads, passive infra-red detectors, door contacts, and similar devices. The
table below summarizes the size and distance wires.
Wire Size
AWG
22
18
Tab. 10.1: Alarm wire guide
You wire alarms either Normally Open (N.O.) (the default) or Normally Closed (N.C.), and
must program the alarm inputs through the page Configuration.
The camera incorporates two types of alarms: Non-supervised and Supervised. In addition to
transmitting an alarm condition, a supervised alarm also transmits a tamper condition.
Depending on how the alarm is configured, a short or a break in the alarm's circuit can trigger
the tamper signal.
Configuring Supervised Alarms (inputs 1 and 2)
To configure Alarm 1 or 2 (pin 5 or 6) for supervision, you must install a 2.2 K end-of-line
resistor in the circuit. Then, you program the alarms, through Configuration, to either
Normally Open (N.O.) or Normally Closed (N.C.).
Notice!
i
Only Alarms 1 and 2 (pins 5 or 6) can be configured for supervision. Once a supervised alarm
is programmed, it does not need to be enabled to indicate a tamper condition.
Configuring a Normally Open Supervised Alarm
1.
2.
2021-08 | 1.4 |
Maximum Distance
mm
feet
meters
0.644
500
152.4
1.024
800
243.8
Install a 2.2 K end-of-line resistor in the alarm circuit.
Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
camera.
Installation Manual
AUTODOME inteox 7000i - 2MP (in-ceiling)
Bosch Security Systems