52
en | Installing the In-Ceiling Mount
5.
6.
7.
8.
F.01U.215.779 | 1.0 | 2011.07
Connect the 24 VAC power wires to the P101 connector in the Interface Box.
To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin
Alarms Out connector plugs with flying leads to the appropriate alarm wires. Then
connect the plugs to their mating connectors P103 and P102 in the Interface Box.
PIN
1
2
3
4
PIN
1
2
3
4
5
6
Figure 4.6 Alarm and Relay Connector Plugs
1
4-pin Alarm Connector
(P102)
Pin Description
1
Alarm Out 1
2
Alarm Out 2
3
Alarm Out 3
4
Alarm Ground
* Low Voltage TTL (3.3V) can also be used.
To connect supervised alarms and relays, attach the appropriate wires to their terminals
on the P104 connector on the Pipe Interface Board. Refer to Section 6 Alarms and Relay
Connections, page 60 for more details on wiring alarms.
Attach the lid to the Interface box:
a.
Align the slots on the lid with the two posts at the rear of the Interface box.
b.
Rotate the lid down.
c.
Squeeze the ground clips, located at the front of the box, against the Interface box
with your fingers before closing the lid to ensure that the lid does not catch on the
ground clips.
d.
Secure the lid to the Interface box by pushing the lid down until the clip on the lid
catches against the box.
Installation Manual
WHITE
BROWN
P102
ORANGE
GREEN
WHITE
BROWN
ORANGE
P103
GREEN
YELLOW
BLUE
*
6-pin Alarm In Connector
2
(P103)
Pin Description
1
Alarm In 3
2
Alarm In 4
3
Alarm In 5
4
Alarm In 6
5
Alarm In 7
6
Alarm Ground
AutoDome 700 Series IP PTZ Camera
1
2
3
4
5
6
7
P104
3
7-pin Relay Connector
(P104)
Pin Description
1
Normally Open
2
COM
3
Normally Closed
4
Earth Ground
5
Analog Alarm 1
6
Analog Alarm 2
7
Ground