Installation: Rear Fed Shower Fittings
Suitable for solid, dry-lined, stud partition, shower cubicle or laminated panel walls. Plan
installation location of the handshower and deluge showerhead before installing fittings kit.
Note: Make sure that the deluge head is not installed over the handshower.
Fix at convenient height for all users. Position so that water sprays down the centre of the
bath, or away from the opening of a shower cubicle. Water should spray away from the
Controller when the Handshower is held on the slide bar.
1
The right angle connector must be fitted to a waterproof, flat and even wall surface. The
screws and wall plugs supplied are suitable for most solid wall installations. Alternative
fixing screws for panel structures are not supplied. Use both fixing points to secure the
right angle connector, be sure to use fixings appropriate for the chosen wall structure.
Using a suitable pipe cutter, trim the pipework back to the required depth from the
finished wall surface. Remove all burrs and sharp edges.
Note: 15mm copper pipe
must be used here.
1300 mm Minimum to
achieve a comfortable
shower height for all users
90°