r Transmitted data
Command
example
Data length
f Example: Transmission of power supply status acquisition command
"00QPW" (CR)
r Received data
Command
example
Data length
f Example: The projector is in standby status
"00000" (CR)
r Error response
Message
Data length
Note
f The projector automatically disconnects from the network immediately after sending the command. Such specifications are made from the
viewpoint of security, such as prevention of illegal operation of the projector by a malicious third party. To send commands continuously,
make a request for network connection every time and send it. For details, see "Communication flow between the server and the client"
(x page 169).
Communication flow between the server and the client
When sending / receiving commands via LAN, refer to the communication flow shown below.
Server: the projector
Client: the control device such as a computer
Chapter 7 Appendix - Technical information
Header
'0'
0x30
1 byte
Header
'0'
0x30
1 byte
1 byte
String
"ERR1"
Undefined control command
"ERR2"
Out of parameter range
"ERR3"
Busy state or no-acceptable period
"ERR4"
Timeout or no-acceptable period
"ERR5"
Wrong data length
4 bytes
Client
First session
Second session
Data section
'0'
Control command
0x30
(ASCII string)
1 byte
Undefined length
Data section
'0'
Control command
0x30
(ASCII string)
Undefined length
Details
Server
Connection query
Sending key
Send first command
Respond first command
Cut off
Connection query
Sending key
Send second command
Respond second command
Cut off
Termination symbol
(CR)
0x0d
1 byte
Termination symbol
(CR)
0x0d
1 byte
Termination symbol
(CR)
0x0d
1 byte
ENGLISH - 169