Leak testing of the appliance shall be in accordance
4.
with the following instructions:
Turn on gas and check supply line connections for
leaks using a soap and water solution.
Bubbles forming indicate a gas leak. Repair all leaks
immediately.
Checking the gas line for leaks
Leak testing must be conducted by the installer according
to the following instructions.
WARNING
DO NOT use a flame of any kind to check for gas leaks.
Turn on gas.
1.
Apply a non-corrosive leak detection fluid to all joints
2.
and fittings in the gas connection between the shut-off
valve and the appliance. Also check gas fittings and
joints in the appliance if the connections may have been
disturbed during installation.
Bubbles appearing around fittings and connections
a
indicate a leak.
If a leak appears, turn off the supply line gas shut-off
3.
valve and tighten the connections.
Retest for leaks by turning on the supply line gas shut-
4.
off valve.
When the leak check is complete and no bubbles
a
appear, the test is complete.
Wipe off all soap solution or detection fluid residue.
5.
Do not continue the installation until all leaks are
a
eliminated.
6.1 Electrical supply circuit requirements
The cord supplied with the gas ranges having an electric griddle requires a NEMA 5-20 receptacle. All other gas units
require a NEMA 5-15 receptacle.
Model
Pxx305Wx
Pxx366Wx
Voltage
120 VAC
120 VAC
Electrical requirements and connection for GAS models en-us
6 Electrical requirements and

Electrical requirements and connection for GAS models

connection for GAS models
Electrical requirements and connection for GAS models
WARNING
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
ON accidentally.
WARNING
Always disconnect appliance from the electric supply
either by disconnecting power cord or shutting off the
breaker at the service panel before servicing the
appliance.
WARNING
This appliance must be properly grounded.
Electrical grounding instructions
This appliance is equipped with a three-prong
grounding plug for your protection against shock hazard
and should be plugged directly into a properly grounded
receptacle. DO NOT cut or remove the grounding prong
from this plug.
CAUTION
Improper grounding or reverse polarization will cause
malfunction, such as continuous sparking of the burner
igniters. This can damage the appliance and can create a
condition of shock hazard.
If the dedicated circuit is not correctly grounded and
polarized, it is the responsibility and obligation of the
installer and user to have the existing receptacle
changed to a properly dedicated grounded and
polarized receptacle.
This must be accomplished by a qualified electrician in
accordance with all applicable local codes and
ordinances. In the absence of local codes and
ordinances, the receptacle replacement shall be in
accordance with the National Electrical Code.
INSTALLER - show the owner the location of the circuit
breaker. Mark it for easy reference.
Dedicated circuit
15 Amps
15 Amps
Phase
Single
Single
17