Step 6: Electrical Requirements, Connection & Grounding
Prior to servicing
appliance,
always
disconnect
appliance
electrical
supply cord from wall recep-
tacle.
Chart
B: E_ectrioa_
Supply
Cirouit
Requirements
MODEL NUMBER
VOLTAGE
CIRCUIT RATING
FREQUENCY
PHASE
P304
120 VAC
10 Amps
60 Hz.
Single
P366
120 VAC
10 Amps
60 Hz.
Single
P364GL
120 VAC
10 Amps
60 Hz.
Single
P364GE
120 VAC
20 Amps
60 Hz.
Single
For these gas range
models,
a neutral
supply
wire
must be provided
from the power
source
(breaker/fuse
panel) because critical range com-
ponents,
including
the
surface
burner
spark
reignition
modules,
require
120 VAC to operate
safely and properly. An improper
120 VAC power
supply
will cause
malfunction,
damage
to this
appliance,
and possibly
create
a condition
of
shock hazard.
If the correct
power supply circuit
is not provided,
it is the responsibility
and obliga-
tion of the installer and user to have proper power
supply connected.
This must be accom slished in
accordance
with all applicable
local codes
and
ordinances
by a qualified
electrician.
In the ab-
sence of local codes and ordinances,
the power
supply
connection
shall be in accordance
with
the National
Electrical
Code.
Observe
all governing
codes
and ordinances
when grounding.
In the absence
of these codes
or ordinances
observe
National
Electrical
Code
ANSIiNFPA
No. 70 current issue.
Electric
wiring
diagrams
and schematics
have
been placed
in the toe kick area of the range for
access by a qualified
service technician.
IMPORTANT
Dedicated,
20 AMP service
is required for model P34GE,
with electric
griddle.
The appliance
must be isolated from the gas supply piping system by closing its individual
manual shut-
off valve during any pressure
testing of the gas supply piping system at test pressures
equal to or less
than 1/2 psig (3.5kPa.).
The appliance
and its individual
shut off valve must be disconnected
from the gas supply piping system
during any pressure
testing
of the system
at test pressures
in excess of 1/2 psig (3.5kPa.).
When checking
the manifold gas pressure,
the inlet pressure
to the regulator
should be at leas 6.0" (14.9
mb) W.C. for natural gas or 11.0" (27.4 mb) for propane.
Do not attempt any adjustment
of the pressure
regulator.