Jøtul GF 520 DV Installation And Operation Instruction Manual page 8

Direct vent gas stove
Table of Contents

Advertisement

130139 Rev 1 GF 520 DV 12/22
Alcove Installation
Maximum Alcove Depth:
Minimum Alcove Width*:
Minimum Alcove Ceiling Height
from floor:
* Alcove clearances are determined through testing in specific
construction configurations which often result in greater clearances
than an open stove installation.
Clearance to Combustible Materials Above
Stove
Minimum Mantle Height from floor: 59 7/8" (1521 mm)
with 24" (610 mm) maximum mantle depth.
Distance to Gas Supply
Suggested gas supply location is within 12" of the rear of the
center line of the stove.
Distance to Electrical Supply
A grounded permanent electrical supply should be installed
within 6 ft. of the center line of the exhaust pipe.
8
24" (607 mm)
44" (1118 mm)
82" (2802 mm)
7 15/16"
202 mm
22"
559 mm
10"
254 mm
1117 mm
Figure 5.2
Alcove Clearances.
82"
2083 mm
59 7/8"
1521 mm
38 7/8"
987 mm
Figure 5.3. Mantel and Ceiling Clearances.
1 1/2"
38 mm
10"
254 mm
44"
24"
610 mm
21"
533 mm
1 1/2"
38 mm
24"
607 mm