SNORKEL TERMINATION:
• HORIZONTAL RUN MUST NOT EXCEED 2 FEET (61
CM).
A 14" (356mm) or 36" (914mm) snorkel termination
is approved in conformance with the vent rise/run and
termination clearance specifications published in this manual.
See figs. 6.9 – 6.10.
The snorkel termination must comply with grade and building
clearance requirements per local and national building codes.
2"
51 mm
Max 18" Length
Min 12" Length
58"
1473 mm
39"
991 mm
Figure 6.9. Optional Snorkel Termination
 Any horizontally terminated vent run must include a minimum 1 ft. (61
cm) vertical rise.
 At minimum vertical run, the total horizontal run (A) must not
exceed 5 ft. (152.4 cm).
5.75" 146mm
24" Vertical Pipe and 90
Degree Elbow
Figure 6.11.
Optional Corner Installation Clearances
14
1.5"
38 mm
55"
1397 mm
69"
1753 mm
16.75"
425 mm
23.5"
597 mm
Max 24"
610 mm
Length
Figure 6.10. Minimal Pipe Exposure Clearances.
 2 FT. MAX. HORIZONTAL RUN (A) TO SNORKEL TERMINATION
36" Snorkel
6" Wall
Thickness
6"
152 mm
90 Degree
Elbow to Unit
18" Pipe
Length
Pipe Length
1.5"
38 mm
44.5"
1130 mm
12" Pipe Length
5.75" 146 mm
16.75"
425 mm
6"
Center Pipe
36"
914 mm
Snorkel
80.5"
2045 mm
7"
178 mm
3.75"
95 mm
45 Degree
Elbow