130139 Rev 1 GF 520 DV 12/22
Fuel Conversion, cont'd.
6. Change the Pilot Injector, Fig 7.3.
• Use the 7/16" wrench to loosen the pilot hood, hold the
pilot mounting bracket with pliers to prevent bending the pilot
bracket.
• Lift the Pilot Hood and remove the pilot injector and replace
with one in fuel conversion kit. Replace the pilot head and
orient the hood to project flame to the Flame Sensor and
burner carry-over ports. Be sure to orient the hood to project
flame to the Flame Sensor and the burner carry-over ports.
7. Flip the Air Shutter. Carefully bend open the Air Shutter
Handle and flip the Air Shutter so it displays "LP". Carefully
bend the Air Shutter Handle back around the Air Shutter.
See fig 7.3
8. Replace the Burner. Tilt the burner assembly downward
to engage the venturi tube with air shutter assembly. BE
CERTAIN THE BURNER IS LEVEL AND SECURELY
ENGAGED WITH THE FRONT SUPPORTS ON THE
FIREBOX FLOOR.
Figure 7.4.
GF 520 DV Control Compartment. Image shown with optional blower.
18
Remove black
rubber gasket
Variable regulator tower
Figure 7.7.
Regulator tower removal and replacement