Jøtul GF 520 DV Installation And Operation Instruction Manual page 24

Direct vent gas stove
Table of Contents

Advertisement

130139 Rev 1 GF 520 DV 12/22
Optional Blower 158333
Kit Contents:
• Left Blower Assembly
• Right Blower Assembly
• Wiring Harness
• Flange Nuts (6)
• Sheet Metal Screws (3)
Tools Required:
• 10mm socket and ratchet
• 1/4" driver
• Light
• Gloves
Read these instructions before beginning the installation.
1. Unpack and check the contents of the blower kit. Contact
your dealer if any damage is evident or parts are missing.
2. Identify the Right Blower Assembly. The Right Blower As-
sembly has the air hole cutout on one side.
3. Attach the pink connectors from the Green Gounding Strap
to the prong at the bottom of the blower as shown in fig.
10.8.
4. With the arrows on the blower facing up and out, rotate the
blower behind the burner gas line and mount to the studs on
the factory installed blower brackets.
Do not connect blower to power supply until all
wire connections have been made.
This blower must be electrically grounded in
accordance with local codes or, in the absence
of local codes, with the current ANSI/NFPA
70, National Electrical Code or CSA C22.1-
Canadian Electrical Code.
This unit is supplied with a three-prong
(grounding) plug for protection against shock
hazard and should be plugged directly into a
properly grounded three-prong receptacle. DO
NOT CUT OR REMOVE THE GROUNDING
PRONG FROM THE PLUG.
Always disconnect the power supply when
performing any service on the stove.
24
• Snapstat
• Snapstat Bracket
• Snapstat Finger Guard Assembly
• Green Grounding Strap
Figure 10.8. Grounding Strap connection point.
Figure 10.9. Install the right side blower.
Figure 10.10. Rotate the Left side blower to fit behind the burner
gas line.