Wiring and Connections
Downloaded from
Elcodis.com
electronic components distributor
to completely remove just one side at a time. Remove the hooks from just
one tab on both sides of the connector and then remove the cover.
2. Insert the flat cable's wires into the socket that was separated in step 1,
align the positions of the wires with the contacts, and lock the contact and
cover pieces together.
Use a vise or other tool to press the pieces together until the hook engages
firmly on the connector's bottom tab.
Compatible cables: 1.27 mm pitch flat cable with 28 AWG 7-conductor
stranded wires
UL2651 (standard cable)
UL20012 (ribbon cable)
UL20028 (color coded cable)
3. When necessary fold over the cable, install a strain relief, and lock it in
place.
4. Connect the assembled MIL connector to an I/O Terminal.
MIL40P Loose-wire Pressure Connection
If you are assembling your own connecting cable with loose wire, assemble
the connectors with the parts listed in the following table. Select the proper
parts for the wire gauge being used.
Part
For 24 AWG wire
Socket
XG5M-4032-N
Partial Cover
XG5S-2001 (See note a.)
Hood Cover
XG5S-5022 (See note b.)
Note a) Two Partial Covers are required for each Connector.
b) When a Hood Cover is being used, a multi-drop wiring DeviceNet
connector cannot be used.
Section 3-5
For 28 or 26 AWG wire
XG5M-4035-N
43