Omron SYSMAC CPM2B-S001M-DRT Operation Manual page 133

Table of Contents

Advertisement

Cycle Time
Special Instructions
Code
Mnemonic
00
NOP
01
END
02
IL
03
ILC
04
JMP
05
JME
06
FAL
07
FALS
08
STEP
09
SNXT
10
SFT
11
KEEP
12
CNTR
13
DIFU
14
DIFD
15
TIMH
16
WSFT
17
ASFT
20
CMP
21
MOV
22
MVN
23
BIN
24
BCD
122
Downloaded from
Elcodis.com
electronic components distributor
ON execution
Conditions (Top: min.; bottom: max.)
time (µs)
0.15
Any
6.2
1.1
1.6
0.95
2.1
20.5
2.9
7.3
5.1
10.4
With 1-word shift register
15.3
With 10-word shift register
39.6
With 53-word shift register
3.2
Any
10.9
Constant for SV
18.8
D M for SV
*
5.5
Any
5.3
Any
9.0
Regular execution, constant for SV
9.6
Interrupt execution, constant for SV
9.8
Regular execution,
10.7
Interrupt execution,
14.0
With 1-word shift register
18.6
With 10-word shift register
1.15 ms
With 2,048-word shift register using
13.0
Shifting 1 word
22.9
Shifting 10 words
1.51 ms
Shifting 2,048 words via
7.0
When comparing a constant to a constant
8.3
When comparing two words
12.1
When comparing two
7.8
When transferring a constant to a word
8.4
When transferring from one word to another
22.8
When transferring
7.9
When transferring a constant to a word
8.4
When transferring from one word to another
22.8
When transferring
15.8
When converting a word to a word
30.3
When converting
14.6
When converting a word to a word
29.0
When converting
D M for SV
*
D M for SV
*
D M
*
D M
*
D M
*
D M to
D M
*
*
D M to
D M
*
*
D M to
D M
*
*
D M to
D M
*
*
Section 8-1
OFF execution time (µs)
2.1
1.6
1.8
2.1
2.5
2.5
6.0
3.6
Reset
IL
JMP
9.2
0.98
0.98
11.9
1.0
1.0
26.2
1.0
1.0
Reset
IL
JMP
3.1
1.2
1.3
Reset
IL
JMP
7.9
5.5
5.6
Shift
IL
JMP
5.1
4.8
0.96
Shift
IL
JMP
5.4
4.7
0.97
Reset
IL
JMP
13.0
12.6
6.1
14.4
14.0
7.5
20.8
20.5
6.1
22.2
22.0
7.5
2.6
2.6
2.6
2.6
2.6
2.6
2.6

Advertisement

Table of Contents
loading

Table of Contents