6.2.3 Connecting the power optimization system

DANGER
DANGER
INFORMATION
Prerequisite Unit dead
The unit can be connected to a power optimization system with a
potential-free contact. The potential-free contact is used to link the
unit to the control.
Risk of personal injury and property damage from electric shock
• Prior to working on the FlexiCombi Team, ensure that the two electrical
circuits inside the unit are de-energized.
• Do not operate the unit with the housing open.
Risk of personal injury and property damage from electric shock
• Before connecting, ensure that the electrical connection line is dead.
• Ensure that the electrical connection line is undamaged.
Each unit must be connected individually.
Do not join the connection lines.
Electrical connection line dead
Housing opened
1. Pull the electrical connection line into the unit through the cable
gland.
2. Route the electrical connection line to the connection terminals.
3. Connect the electrical connection line in accordance with the
wiring diagram.
4. Secure the electrical connection line with cable ties.
5. Register the power optimization system in the basic settings of the
control (see "Making the basic settings of the control").
6. Fill out the Start-up operation report.