3-4. POWER SWITCH
REPLACEMENT
Figure 3-1
Figure 3-2
Figure 3-3
Feb. 2011
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Using a Phillip's head screwdriver, remove the four screws
securing the front panel.
2. Pull panel down, pull connectors from the back of it, and
remove panel from unit.
3. Using 5/16" socket, remove the 4 nuts securing the control
cover and remove cover. Figure 3-1.
4. Pull wires from switch and check across the 2 terminals for
continuity. Figure 3-2. With switch in ON position, the
circuit should be closed. In the OFF position, the circuit
should be open. If the switch is defective, continue with
step 5.
5. Pinch the tabs on the rear of the switch and pull the switch
through the front of the panel. Figure 3-3.
6. Replace with new switch in reverse order and unit is now
ready for use.