Installing the unit
Requirements The floor must support the weight of the unit
22
Floor without steam barrier
In the case of floors without a steam barrier, the floor plates are bolted
to the floor using the bolts provided.
a
A
e
d
Image: A: Position of floor plate; B: floor plate bolted to the floor
a Cap nut
b Holding plate
c Upright bolt
The floor must be clean and suitable for the manner of fastening
Unit set up and aligned in accordance with the planning drawing
1. Insert the floor plate from the fastener set into the holding plate as
shown in the drawing.
2. Screw on the cap nuts hand-tight.
3. Align the floor plates in position 1-1 or 2-2 on the unit leg as
shown in the drawing and mark the fastening holes in the floor.
4. Mark the position of all unit legs on the floor.
5. Using appropriate lifting gear, move the unit so that the holes can
be drilled in the floor.
6. Drill holes matching the diameter of the anchor sufficiently deep in
the floor.
7. Carefully place the unit in the installation position.
8. Screw on the cap nuts and remove the holding plate from the floor
plate.
9. Screw the floor plate to the floor using the anchors and bolts
supplied.
10.Ensure that sealing of the floor is restored after the bolts are
screwed in.
11.Place the holding plate on the floor plate and fasten in place with
cap nuts.
12.Fill out the start-up operation report.
Floor with steam barrier
In the case of floors with a steam barrier, the floor plates are not
screwed to the floor but fastened with the enclosed adhesive.
Installation instructions
B
f
b
c
d Floor plate
e Lag bolt
f Unit leg