Connecting the unit
INFORMATION
Prerequisite Unit dead
30
• Ensure that the electrical connection line is undamaged.
c
d
Image: Connecting the electrical connection line
a Connection terminals
b Cable tie
Each unit must be connected individually.
Do not join the connection lines.
Electrical connection line dead
Unit adjusted to supply voltage
Side wall open
1. Feed the electrical connection line into the unit through the
threaded cable connection.
2. Connect the power connection cable in accordance with the wiring
diagram.
3. Secure the electrical connection line with cable ties.
4. Tighten the threaded cable connection securely to provide strain
relief.
5. Close the housing (see "Opening and closing the housing").