MODE Switch Setting for System Example 2
The MODE switch needs to be set prior to operating a sys-
tem connected as shown in Example 2.
1
2
Bit 3 should be set to OFF.
Bit 5 should be set to OFF when the controller is placed
in an intermediate position, or set to ON when it is con-
nected at the chain end.
16
OFF
ON
3
4
5
6
7
8
Controller Number Setting (PS
A 10-position rotary switches provided on the rear for spec-
ifying the unit number of the WV-CU360C controller in a
PS
Data system.
1. Remove the DC plug from the rear of the controller.
2. Use a screw driver to rotate the switch so that the arrow
comes to the number you wish.
CONTROLLER No.
3. Connect the DC plug to the controller.
Controller No. Switch of WV-CU360C
0
1
2
3
4
5
6
7
8
9
Notes:
• Set the switch to #1 when a single controller is used in
the system.
• Specify a unique number for each controller when con-
necting multiple controllers in the system. One con-
troller within the multiple controller system must be
assigned the number 1.
• Positions #0 and #9 are reserved and cannot be used.
Data)
0
Controller No.
Reserved
1
2
3
4
5
6
7
8
Reserved