Dip Switch Setting; Controller Number Setting - Panasonic WV-CU360C Operating Instructions Manual

System controller
Table of Contents

Advertisement

DIP Switch Setting

An 8-bit DIP switch mounted on the rear panel specifies communication mode, etc. The default position is marked with an
asterisk *.

Controller Number Setting

Set this switch always to 1 when using the System
Controller in a System 850.
CONTROLLER No.
72
Function
Bit 1
System ID
Bit 2
System ID
Bit 3
System ID
Bit 4
Reserved
Bit 5
Line termination
Bit 6
Operation mode
Bit 7
Baud Rate Selection
Bit 8
Repeat Transmissions
0
0
CONTROLLER No.
MODE
DATA
SW position
OFF
*
*
*
*
Off
Operator*
Auto-selection*
1 time*
Switch Setting Procedures
Set the MODE DIP switch and CONTROLLER NO. switch as
follows.
1. Remove the DC plug from the rear of the controller.
2. Set the switches as follows.
• Bit 1 should be set to OFF*.
• Bit 2 should be set to ON.
• Bit 3 should be set to OFF*.
• Bit 4 should be set to OFF*.
• Bit 5 should be set to ON* when connecting with a
System 850 in a home run (one to one) fashion.
• Bit 6 should be set to OFF* (Operator) normally, or ON
(Administrator) when setting up the controller.
• Bit 7 should be set to ON. The baud rate is selected in
the controller setup.
• Bit 8 should be set to OFF* normally.
3. Connect the DC plug to the controller.
DC 9V IN
ON
See below
See below
See below
Not used
On*
Administrator
Set up from CU360
3 times
1
2
3
4
5
6
7
8
MODE
OFF
ON