H5CC
Operating Procedures of the H5CC-AWSD
Operation in Run Mode
Set the digits for the set values using the corresponding UP1 to UP6 Keys (DW1 to DW6 Keys).
Forecast Value Setting
0.0
Present value
0.0
Set value
*
0.0
Present value
0.0
Forecast set value
Operation in Function Setting Mode
Change to Function Setting Mode.
Power ON
Run mode
* Use UP1+UP3 to move up and
DW1+DW3 to move down
timr
----.--
*
outm
a
*
iflt
20m5
*
imod
npn
*
From
To
next page
next page
34
* Each time the UP1 + UP3 or
DW1 + DW3 are pressed,
the sub-display will switch
between the set value
("SET" is lit) and the forecast
set value ("1" is lit).
UP1+UP3 or DW1+DW3
*1
(Press and hold for 2 s)
Function
setting mode
*2
UP1+UP3 or DW1+DW3
(Press and hold for 2 s)
The characters displayed in reverse video are the default settings. In the function setting mode, the status indicators of the
keys that can be set light up.
(Example) In the case of the set value upper limit
A value from 1 to 999999 can be set, and therefore the status indicators of the UP1 to UP6 Keys (DW1 to DW6 Keys) light up.
sl1h
Set value
upper limit
999999
• Set the time range using the UP1 Key (DW1 Key).
Time range
----.--
s
For details, refer to the Time Range List.
• Set the output mode using the UP1 Key (DW1 Key).
Output
a
f-1
modes
(A)
(F-1)
• Set the input signal width using the UP1 Key (DW1 Key).
Input signal
20ms
1ms
(20 ms)
(1 ms)
• Set the NPN/PNP mode using the UP1 Key (DW1 Key).
NPN/PNP
npn
pnp
input
(NPN input)
(PNP input)
Absolute Value Setting
0.0
0.0
*
0.0
0.0
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the
mode is changed to run mode. Also, when settings are changed, the timer is reset (time
initialized and output turned OFF).
• Set the digits for the set values using the corresponding
UP1 to UP6 Keys (DW1 to DW6 Keys).
1
999999
(1)
(999999)
-----.-
......
------
s
h
Present value
* Each time the UP1 + UP3 or
Set value 1
DW1 + DW3 are pressed,
the sub-display will switch
between set value 1 ("SET
1" is lit) and set value 2
Present value
("SET 2" is lit).
Set value 2
Time Range List
Display
0.01 s to 9999.99 s
----.--
---.---
s
s
(default setting)
-----.-
0.1 s to 99999.9 s
s
------
1 s to 999999 s
s
--:--:--
0 h 0 min 01 s to 99 h 59 min 59 s
h m s
-----.-
0.1 min to 99999.9 min
m
------
1 min to 999999 min
m
----:--
0 h 01 min to 9999 h 59 min
h m
-----.-
0.1 h to 99999.9 h
h
------
1 h to 999999 h
h
---.---
0.001 s to 999.999 s
s
Set Value