Omron H5CC Manual page 7

Digital timer
Hide thumbs Also See for H5CC:
Table of Contents

Advertisement

Characteristics
Accuracy of operating time and setting error
(including temperature and voltage
influences)
Insulation resistance
Dielectric strength
Impulse withstand voltage
Static immunity
Destruction
Vibration resistance
Malfunction
Destruction
Shock resistance
Malfunction
Mechanical
Life expectancy
Electrical
Weight
* Refer to Electrical Life Test Curve.
Electrical Life Test Curve (Reference Values)
1,000
500
100
30 VDC L/R = 7 ms
50
10
250 VAC cosI = 0.4
0
1
2
3
A maximum current of 0.15 A can be switched at 125 VDC (cosφ =1)
and a maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
Power-ON start: ±0.01%±0.05 s max. *1
Signal start: ±0.005%±0.03 s max. *1
Signal start for transistor output model: ±0.005%±3 ms max. *1 *2
If the set value is within the sensor waiting time at startup the control output of the H5CC will not turn ON until the
sensor waiting time passes.
*1. The values are based on the set value.
*2. The value is applied for a minimum input signal width of 1 ms.
100 MΩ min. (at 500 VDC)
between current-carrying terminal and exposed non-current-carrying metal parts, between non-continuous contacts
2,900 VAC, 50/60 Hz for 1 min between current-carrying terminal and operating section
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits
for models other than the H5CC-A11F and H5CC-L8E@
(1,500 VAC for 12 to 48 VDC/24 VAC)
1,500 VAC, 50/60 Hz for 1 min between control output, power supply,
and input circuits (for models other than the H5CC-L8E@) for H5CC-@SD
2,000 VAC, 50/60 Hz for 1 min between control output, power supply,
and input circuits (for models other than the H5CC-L8E@) for other models
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
5 kV (between power terminals) for 100 to 240 VAC, 1.0 kV for 24 VAC/12 to 48 VDC
7.4 kV (between current-carrying terminal and operating section)
Malfunction: 8 kV
Destruction: 15 kV
10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each
10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each
300 m/s
2
in three directions, three cycles
100 m/s
2
in three directions, three cycles
10,000,000 operations min.
(under no load at switching frequency of 1,800 operations/h and ambient temperature of 23°C)
100,000 operations min.
(5 A at 250 VAC, resistive load at 1,800 operations/h and ambient temperature of 23°C) *
Approx. 115 g (Timer only)
250 VAC/30 VDC
cosI = 1
4
5
Load current (A)
H5CC
7 7

Advertisement

Table of Contents