Omron H5CC Manual page 11

Digital timer
Hide thumbs Also See for H5CC:
Table of Contents

Advertisement

Nomenclature
Display Section
1. Key Protection Indicator
Lit when the key protect switch is ON.
2. Control Output Indicator
Forecast value setting (for the H5CC-AWSD)
Forecast output ON: OUT 1 is lit.
Control output ON: OUT 2 is lit.
Absolute value setting (for the H5CC-AWSD)
Control output 1 ON: OUT 1 is lit.
Control output 2 ON: OUT 2 is lit.
3. Reset Indicator
(yellow)
Lit when the reset input or Reset Key is ON.
4. Present Value Display
(Main display)
(Character height: 10 mm, white)
5. Time Unit Indicators
(green)
(If the time range is 0 min, 0 h, 0.0 h, or 0 h
0 min, these indicators flash to indicate
timing operation.)
6. Set Value Display
(Sub-display)
(Character height: 6 mm, green)
7. Set Value 1, 2 Indicator
(green)
Character Size
Character Size
for Main Display
for Sub-display
10mm
6mm
(yellow)
1
(yellow)
2
3
7
10
10. Reset Operation (UP6+DW6) *
1. Press RST keys (UP6+DW6) simultaneously for at least one second.
2. LED on each key starts blinking.
Do not release the keys until the LED starts blinking. Otherwise
the setting value may change. If not blink, that is because the
keys are not pressed simultaneously. In this case, release the
keys after pressing for at least 1 second, and restart from 1.
3. Press and hold until the LED turns off.
If you release the keys while blinking, the reset operation will be interrupted.
11. Mode Operation (UP1+UP3 or DW1+DW3)
<Change of setting item>
1. Press MODE keys (UP1+UP3 or DW1+DW3) simultaneously to switch setting items.
<Move to Function Setting Mode>
1. Press MODE key (UP1+UP3 or DW1+DW3) for at least 2
seconds simultaneously.
2. LEDs on UP1 (DW1) and UP3 (DW3) key start blinking.
Do not release the keys until the LEDs start blinking. Otherwise
the setting value may change. If not blink, that is because the
keys are not pressed simultaneously. In this case, release the
keys after pressing for at least one second, and restart from 1.
3. Press and hold until the LED turns off. If you release the keys
during blinking, the mode will not be moved to Function Setting
Mode.
12. Status indicator
<When Run mode is not selected.>
· When the indicator display mode is ON
The ratio of the measurement value to the set value is displayed from 0 to 100%.
· When the indicator display mode is all off or all lit
All off or all lit display.
Note. When you press the Up Key or the Down Key, the status indicator display goes off, and the
pressed key lights up or blinks.
<When Function Setting Mode is not selected>
· The keys that can be set light up for notification.
13. Key-protect Switch
(Default setting)
H5CC
TIMER
4
5
6
8
12
9
11
Switches
OFF
ON
(Disable)
(Enable)
Operation Keys
8. Up Keys (UP1 to UP6)
(UP1, 2, 3, 4, 5, 6 from right to left)
9. Down Keys (DW1 to DW6)
(DW1, 2, 3, 4, 5, 6 from right to left)
DW1+DW3
H5CC
11

Advertisement

Table of Contents
loading

Table of Contents