H5CC
Operating Procedures of the H5CC-A@/L@
Setting Procedure Guide
Settings for Timer Operation *
Use the following settings.
Settings for Twin Timer Operation *
Refer to page 26.
* "Timer" is set in the default settings. Refer to page 33 for information on switching models.
Step1
Change to Function Setting Mode.
Power ON
UP1+UP3 or DW1+DW3
Run mode
UP1+UP3 or DW1+DW3
* Use UP1+UP3 to move up and
DW1+DW3 to move down
timr
----.--
*
timm
up
*
outm
a
*
otim
hold
*
iflt
20m5
*
imod
npn
*
From
To
next page
next page
16 16
For details on operations in run mode, refer to page 19.
*1
(Press and hold for 2 s)
Function
setting mode
*2
(Press and hold for 2 s)
The characters displayed in reverse video are the default settings. In the function setting mode, the status indicators of the keys that
can be set light up.
(Example) In the case of the
Output time
A value from 0.01 to 99.99 s can be set, and therefore the status indicators of the UP1 to UP4 Keys (DW1 to DW4 Keys) light up.
otim
hold
Output time
hold
(Output hold)
• Set the time range using the UP1 Key (DW1 Key).
Time range
----.--
s
For details, refer to the Time Range List.
• Set the timer mode using the UP1 Key (DW1 Key).
Timer mode
up
down
(UP)
(DOWN)
• Set the output mode using the UP1 Key (DW1 Key).
Output
a
a-1
a-2
modes
A-1)
A-2)
(
(
(A)
Note: Only A-2, b, E, and Z can be selected for the H5CC-L8E@.
• Set each digit using the individual UP1 to UP4 Keys (DW1 to DW4 Keys).
hold
0.01
Output time
(Output hold)
(0.01 s)
(If the output time is set to 0.00,
Note: Displayed for modes A, A-1, A-2, A-3, b, b-1 and S only.
• Set the input signal width using the UP1 Key (DW1 Key).
20ms
1ms
Input signal
(20 ms)
(1 ms)
Note: Displayed only when the model is not H5CC-L8E@ or H5CC-A11F.
• Set the NPN/PNP input mode using the UP1 Key (DW1 Key).
NPN/PNP
npn
pnp
input
(NPN input)
(PNP input)
Note: Displayed only when the model is H5CC-A@ or H5CC-A11@. (However, not displayed for H5CC-A11F.)
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the
mode is changed to run mode. Also, when settings are changed, the timer is reset (time
initialized and output turned OFF).
0.01
99.99
(0.01 s)
(99.99 s)
-----.-
......
------
s
h
a-3
b
b-1
b-5
A-3)
b)
b-1)
b-5)
(
(
(
(
99.99
(99.99 s)
hold
is displayed.)
Time Range List
Display
0.01 s to 9999.99 s
----.--
(default setting)
s
-----.-
0.1 s to 99999.9 s
s
------
1 s to 999999 s
s
--:--:--
0 h 0 min 01 s to 99 h 59 min 59 s
---.---
s
h m s
-----.-
0.1 min to 99999.9 min
m
------
1 min to 999999 min
m
----:--
0 h 01 min to 9999 h 59 min
h m
-----.-
0.1 h to 99999.9 h
h
------
1 h to 999999 h
h
---.---
0.001 s to 999.999 s
s
c
d
e
f
g
h
z
C)
d)
E)
F)
G)
H)
Z)
(
(
(
(
(
(
(
Set Value
s
S)
(