Display Code
ENG: 00000-00
00064-04
Oil pressure switch error
00064-01
Oil pressure descend error
00CB2-01
DPF intermediate temperature sensor temperature abnormal low temperature
7F94D-00
Overaccumulation (method C)
7F94E-00
Overaccumulation (method P)
7F951-0B
Regeneration defect (stationary regeneration not performed)
7F94F-07
Regeneration defect (stationary regeneration failure)
00E88-10
Ash cleaning request 1
00E88-00
Ash cleaning request 2
00E87-10
Stationary regeneration standby
00CAA-00
DPF inlet temperature sensor temperature abnormal high
00CB3-00
DPF differential pressure sensor differential pressure abnormal high
00CB2-00
DPF intermediate temperature sensor temperature abnormal high (post-injection failure)
00E87-00
Backup mode
00066-0D
EGR low pressure side sensor (Abnormal learning value)
004B9-0D
EGR high pressure side sensor (Abnormal learning value)
00CB3-0D
DPF differential pressure sensor (Abnormal learning value)
7F94B-06
High-pressure pump drive circuit (Low side GND short-circuit)
00279-03
High-pressure pump drive circuit (High side VB short-circuit)
7F94C-0B
High-pressure pump drive circuit (Pump overload error)
7F94C-06
High-pressure pump drive circuit (Drive current (high level))
7FCE1-00
Rail pressure fault (The actual rail pressure is too high during PRV limp home)
7FCCE-00
Rail pressure fault (The time of PLV valve opening error)
7FCE3-00
Rail pressure fault (Injector B/F temperature error during PLV4 limp home)
7FCCC-09
Rail pressure fault (Controlled rail pressure error after PLV valve opening)
7FCC4-07
Rail pressure fault (Operation time error during RPS limp home)
7FCC6-0D
IQA corrected injection amount for injector 1 error
7FCC7-0D
IQA corrected injection amount for injector 2 error
7FCC8-0D
IQA corrected injection amount for injector 3 error
7FCC9-0D
IQA corrected injection amount for injector 4 error
00B86-06
Overload on the drive H bridge circuit of throttle valve
7FCCF-06
Actuator drive circuit 3 short to ground
7FCD1-0C
AD converter fault 1
7FCD2-0C
AD converter fault 2
7FCD3-0C
External monitoring IC and CPU fault 1
7FCD4-0C
External monitoring IC and CPU fault 2
7FCD5-0C
ROM fault
7FCD6-0C
Shutoff path fault 1
7FCD7-0C
Shutoff path fault 2
7FCD8-0C
Shutoff path fault 3
7FCD9-0C
Shutoff path fault 4
7FCDA-0C
Shutoff path fault 5
7FCDB-0C
Shutoff path fault 6
7FCDC-0C
Shutoff path fault 7
7FCDD-0C
Shutoff path fault 8
7FCDE-0C
Shutoff path fault 9
7FCDF-0C
Shutoff path fault 10
7FCE0-00
Recognition error of engine speed
00E87-09
Recovery regeneration failure
00E87-07
Recovery regeneration prohibition
7FCC0-00
Use of non-recommended fuels and lubricating oils