Fuel Feed Device (Optional) (ZX50U-5N, 60USB-
5N)
This device feeds fuel by electrical pump (3).
d
CAUTION: This device is not incorporated with an
auto-stop function when fuel is filled up. Be sure to
manually stop filling while monitoring fuel level with
level gauge (5).
Fuel Feeding Operation
1. Park the machine following the same procedures as
described on page 7-7 Preparation for Inspection and
Maintenance.
2. Open the tank cover following procedures as described
on page 7-9 Opening/Closing Tank Cover (1).
3. Pull out hose (7) stored in this device. Set the hose end
strainer (2) into the fuel tank.
4. Remove fuel tank cap (4) of the device.
IMPORTANT: If cap (4) is not removed, pressure in the
tank will increase and the pump performance will be
degraded. It will also shorten the service life of the
pump.
5. Turn power switch (8) of electrical pump (3) to ON
position and start fueling.
6. Refill fuel while checking the level gauge (5) float. Stop
fueling by turning switch (8) of electrical pump (3) OFF
before fuel is filled up.
7. Close fuel tank cap (4). Put hose (7) in the device. Be sure
to insert strainer (2) at the end of hose into holder (6).
IMPORTANT: Take care not to allow dirt and/or water to
enter the fuel tank when fueling. Wipe off any spilled
fuel.
OPTIONAL ATTACHMENT
FUEL FEED DEVICE
13-14
7
6
1
2
3
4
MADC-13-001
8
MADC-13-003