Hitachi ZAXIS 30U-5N Operator's Manual page 207

Hydraulic excavator
Table of Contents

Advertisement

d
CAUTION: Do not spill oil while adding oil. Spilled oil
may cause fires.
12. Fill the engine with recommended oil via oil filler (2).
Check that oil level is between the circle marks on oil
level gauge (1) after 15 minutes.
Model
ZX30U-5N, 35U-5N
ZX50U-5N
ZX60USB-5N
f
NOTE: Refer to the recommended oil and grease chart on
page 7-16 for the brand names of oils.
13. Securely tighten oil filler cap (2).
14. Start the engine. Run the engine at slow idle for 5
minutes.
15. Stop the engine. Remove the key from the key switch.
16. Check for any leakage.
17. After 15 minutes, check oil level on the dipstick and add
or drain oil to maintain proper oil level. (The oil level
should be between the upper and lower limit marks on
the oil level gauge.) (Refer to 7-24)
MAINTENANCE
Quantity
6.7 L (1.8 US gal)
7.4 L (2.0 US gal)
10.5 L (2.8 US gal)
1
7-27
MADB-07-011