Replacing Fuses

--- as required
If any electrical equipment fails to operate, first check the
fuses.
IMPORTANT: Install fuse with correct amperage rating to
prevent electrical system damage from overload.
f
NOTE:
 One each spare fuse for respective fuse capacities is
provided in the fuse box.
ZX30U-5N, 35U-5N
5 A
MONITOR ACC
5 A
A/C PANEL, CAB
20 A CAB SOCKET
5 A
TRAVEL RELAY
10 A OPTION, ALARM
5 A
ENGINE
5 A
PILOT SHUT OFF
ZX50U-5N, 60USB-5N
5 A
MONITOR ACC
5 A
A/C PANEL, CAB
20 A CAB SOCKET
5 A
LS CONTROL
10 A OPTION
5 A
ENGINE
5 A
PILOT SHUT OFF
MAINTENANCE
5 A
HORN
5 A
MONITOR B, RADIO
25 A LIGHT
10 A MAIN RELAY
5 A
START
25 A A/C
10 A WIPER, WASHER
5 A
TRAVEL, ILLUMI.
20 A POWER SOCKET
5 A
HORN
5 A
MONITOR B, RADIO
25 A LIGHT
5 A
START
25 A A/C
10 A WIPER, WASHER
5 A
TRAVEL, ILLUMI.
20 A POWER SOCKET
7-76
ZX30U-5N, 35U-5N
ZX50U-5N, 60USB-5N
MADB-07-036
MADG-07-012